ETEP lights

ARTICLES

JPI EDM and Electronics International engine monitor data: getting it out, reading it

An engine monitor measures the temperature of each cylinder, at the exhaust and at the head, and keeps those readings in memory flight after flight. Read well, they show a spark plug that does not fire, a plugged injector or uneven cooling. How to get the data out of a JPI EDM or an Electronics International instrument, and what to look for.

All articles·Published ·7 min read

What an engine monitor measures

A monitor such as the J.P. Instruments (JPI) EDM or the Electronics International (EI) CGR-30P displays and records, cylinder by cylinder, the exhaust gas temperature (EGT) and the cylinder head temperature (CHT), with, depending on the installation, oil temperature and pressure, engine speed, manifold pressure, fuel flow, volts and amps. The EDM also works out the spread between the highest and the lowest EGT (DIF) and monitors the cooling of every cylinder head (CLD).

JPI EDM: the memory and the download

According to the EDM-960 Pilot's Guide, the EDM compresses and records all displayed parameters once every six seconds by default, an interval that can be set from 2 to 500 seconds, even in flight: changing it in flight closes the current flight file and starts a new one. Recording typically begins when EGTs are above 500 °F or RPM above 500. All data is time-stamped by the EDM's clock, set when the instrument is first programmed. When the memory is full, the oldest data is discarded to make room for the newest; its capacity depends on the configuration and on how fast the parameters change.

On an EDM with a USB port on its face, the download is done with the instrument powered:

  1. plug in the USB flash drive; the display shows DOWNLOAD: NEW;
  2. tap STEP to copy only the data recorded since the last download, or tap CHANGE to see DOWNLOAD: ALL, then STEP to copy everything;
  3. wait for the copy to finish without interrupting it: the display shows DONE, then returns to normal operation;
  4. remove the drive.

In either case, no data is erased from the EDM. JPI says the drive must be formatted FAT or FAT32 (not NTFS or exFAT), and advises starting with an empty drive. On an EDM without the internal USB option, you plug in a USB download box, choose DUMP NEW or DUMP ALL on the EDM, and the box writes a .JPI file to the drive.

That compressed data is read with JPI's software. EzTrends transfers the data from the EDM, decompresses it and plots it; EzSave downloads the flights and saves each one as a CSV file, and only CSV files created by EzSave open in EzTrends.

Electronics International: one CSV file per power-up

EI's CGR-30P records up to 1,500 flights before it records over the oldest one. The USB and Data Recording screen, not accessible while the engine runs, copies the flights to a USB stick and sets the interval between two records. Each flight is a comma-delimited file that a spreadsheet opens directly.

The file name says what it holds: Flt0012_20130910F.csv is the 12th flight recorded, on 10 September 2013. The last letter gives its status: P, the instrument was only powered up; E, the engine was running; F, the aircraft flew and the flight timer started. The number increments at each power-up and goes back to 1 after 1,500: to find the flights, look for the F files.

The file starts with 11 header lines: aircraft ID, software version, local time, flight number, engine hours and tach time, data logging interval, unit ID. The 12th line holds the labels, each made of the function and its unit separated by a semicolon, such as F.FLOW;G/HR. The data follows, with the position if the GPS is enabled. The time comes from the instrument's clock, where you set the date, the local time and the Zulu time.

What the curves show

The EDM-960 guide gives typical values for most general aviation engines, with the warning that your engine's may fall outside them:

MeasurementTypical value (JPI guide)
EGT in cruise1,350 °F for engines under 200 hp; 1,550 °F for high-performance engines
EGT spread (DIF)70 to 90 °F with fuel injection; 120 to 150 °F with a carburettor
CHT350 °F normally aspirated (OAT 60 °F); 410 °F turbocharged
CHT spread50 to 70 °F (100 °F with gasket probes)
Oil temperature200 °F
Oil pressure30 to 60 psi, depending on the aircraft
Cylinder head coolingless than 50 °F a minute

The guide insists above all on patterns. In the climb, EGTs and CHTs should be consistent with past climbs. At run-up, on a single magneto, all EGTs should rise by about 50 °F; a large drop on one cylinder may be a fouled spark plug. Its engine diagnosis chart matches symptoms with probable causes:

  • an EGT rise of 75 to 100 °F on one cylinder in flight: a spark plug not firing (fouled, faulty, or its wire);
  • in the climb, one EGT 300 °F above the others: a plugged injector or, on an engine with a carburettor, a leaking manifold gasket;
  • loss of EGT on one cylinder with a rough engine: a stuck valve; loss of EGT with a probe message: a failed probe or wire harness;
  • an increase in DIF at low RPM: low compression;
  • a decrease in EGT on all cylinders: less induction airflow, carburettor or induction ice;
  • a slow rise in EGT with a low CHT: a burned exhaust valve;
  • high CHTs on the cylinders of one side: an obstruction under the cowling, misplaced baffling, a misaligned cowl flap, a bird nest;
  • a rapid rise in the CHT of one cylinder: detonation, which calls for reducing power.

The mixture can be checked too. In cruise, the EDM's LeanFind function finds the first and the last cylinder to reach peak EGT as you lean. The difference in fuel flow between those two peaks, which JPI also calls the “GAMI spread”, shows how well the injectors are balanced: the smaller it is, the better. For rich of peak operation, the guide quotes a final mixture of 20 to 80 °F rich of peak, depending on the engine.

Why read the data again

The pilot reads it after a flight to check the mixture setting and catch an alarm that went unnoticed; the owner, to follow a cylinder over dozens of hours; the mechanic, to guide a troubleshooting. Comparing is what helps: the same cylinder from one flight to the next, the cylinders against each other in cruise, today's climb against the earlier ones. So keep every download, dated and filed by aircraft, rather than relying on the instrument's memory, which ends up being overwritten.

One caution about time: the time of an EDM or a CGR-30P comes from the clock set by hand in the instrument. Check it before lining up the engine file with another log of the same flight.

Sources

  1. Pilot's Guide, Engine Data Management EDM-960 Primary J.P. Instruments, revision C (March 2011)
  2. FAQ — Downloading J.P. Instruments
  3. Software downloads J.P. Instruments
  4. FAQ — EzTrends issues J.P. Instruments
  5. CGR-30P Operating Instructions Electronics International, OI 0702131, revision B (2 July 2013)

Texts read on the date of the article. For regulations, only the official version is authentic.